736 research outputs found

    Imaging quality and prostate MR: it's time to improve

    Get PDF
    The PI-RADS guidelines set out the minimal technical requirements for the acquisition of multiparametric magnetic resonance imaging (mpMRI) of the prostate. However, the rapid diffusion of this technique has inevitably led to variability in scan quality among centres across the UK and the world. Suboptimal image acquisitionreduces the sensitivity and specificity of this technique for the detection of clinically significant prostate cancer and result in clinicians losing confidence in the technique.Two expert panels (one from the UK and one from the ESUR/ESUI) have stressed the importance to establish quality criteria for the acquisition ofmpMRI of the prostate.A first attempt to address this issue has been the publication of the Prostate Imaging Quality (PI-QUAL) score, whichassesses the mpMRI quality against a set of objectivecriteria (PI-RADS version 2.1 guidelines) together with criteria obtained from the image.PI-QUAL represents the first step towards the standardisation of a scoring system toassess the quality of prostate mpMRIprior to reporting and allows clinicians to have more confidence in using the scan to determine patient care. Further refinements after robust consensus among experts at an international level need to be agreed before its widespread adoption in the clinical setting

    Magnetic resonance imaging in active surveillance-a modern approach

    Get PDF
    In recent years, active surveillance has been increasingly adopted as a conservative management approach to low and sometimes intermediate risk prostate cancer, to avoid or delay treatment until there is evidence of higher risk disease. A number of studies have investigated the role of multiparametric magnetic resonance imaging (mpMRI) in this setting. MpMRI refers to the use of multiple MRI sequences (T2- weighted anatomical and functional imaging which can include diffusion-weighted imaging, dynamic contrast enhanced imaging, spectroscopy). Each of the parameters investigates different aspects of the prostate gland (anatomy, cellularity, vascularity, etc.). In addition to a qualitative assessment, the radiologist can also extrapolate quantitative imaging biomarkers from these sequences, for example the apparent diffusion coefficient from diffusion-weighted imaging. There are many different types of articles (e.g., reviews, commentaries, consensus meetings, etc.) that address the use of mpMRI in men on active surveillance for prostate cancer. In this paper, we compare original articles that investigate the role of the different mpMRI sequences in men on active surveillance for prostate cancer, in order to discuss the relative utility of the different sequences, and combinations of sequences. We searched MEDLINE/PubMed for manuscripts published from inception to 1st December 2017. The search terms used were (prostate cancer or prostate adenocarcinoma or prostatic carcinoma or prostate carcinoma or prostatic adenocarcinoma) and (MRI or NMR or magnetic resonance imaging or mpMRI or multiparametric MRI) and active surveillance. Overall, 425 publications were found. All abstracts were reviewed to identify papers with original data. Twenty-five papers were analysed and summarised. Some papers based their analysis only on one mpMRI sequence, while others assessed two or more. The evidence from this review suggests that qualitative assessments and quantitative data from different mpMRI sequences hold promise in the management of men on active surveillance for prostate cancer. Both qualitative and quantitative approaches should be considered when assessing mpMRI of the prostate. There is a need for robust studies assessing the relative utility of different combinations of sequences in a systematic manner to determine the most efficient use of mpMRI in men on active surveillance

    A critical comparison of techniques for MRI-targeted biopsy of the prostate

    Get PDF
    MRI-targeted biopsy is a promising technique that offers an improved detection of clinically significant prostate cancer over standard non-targeted biopsy. It is established that prostate MRI is of use in both the primary and repeat biopsy setting for the detection of significant prostate cancer. There are three approaches to targeting biopsies to areas of interest seen on prostate MRI. They each rely on the acquisition and reporting of a diagnostic quality multi-parametric MRI scan used to identify areas of interest, and the subsequent use of those diagnostic quality images in combination with real-time images of the prostate during the biopsy procedure. The three techniques are: visual registration of the MRI images with a real-time ultrasound image; software-assisted fusion of the MRI images and the real-time ultrasound images, and in-bore biopsy, which requires registration of a diagnostic quality MRI scan with a real time interventional MRI image. In this paper we compare the three techniques and evaluate those studies where there is a direct comparison of more than one MRI-targeting technique. PubMed was searched from inception to November 2016 using the search terms (cognitive registration OR visual registration OR fusion biopsy OR in-bore biopsy OR targeted biopsy) AND (prostate cancer OR prostate adenocarcinoma OR prostate carcinoma OR prostatic carcinoma OR prostatic adenocarcinoma) AND (MRI OR NMR OR magnetic resonance imaging OR mpMRI OR multiparametric MRI). The initial search included 731 abstracts. Eleven full text papers directly compared two or more techniques of MRI-targeting, and were selected for inclusion. The detection of clinically significant prostate cancer varied from 0% to 93.3% for visual registration, 23.2% to 100% for software-assisted registration and 29% to 80% for in-bore biopsy. Detection rates for clinically significant cancer are dependent on the prevalence of cancer within the population biopsied, which in turn is determined by the selection criteria [biopsy naĂŻve, previous negative biopsy, prostate specific antigen (PSA) selection criteria, presence of a lesion on MRI]. Cancer detection rates varied more between study populations than between biopsy approaches. Currently there is no consensus on which type of MRI-targeted biopsy performs better in a given setting. Although there have been studies supporting each of the three techniques, substantial differences in methodology and reporting the findings make it difficult to reliably compare their outcomes

    Progress in Prostate MRI Quality

    Get PDF

    Magnetic Resonance Imaging–guided Active Surveillance of Prostate Cancer: Time to Say Goodbye to Protocol-based Biopsies

    Get PDF
    Traditional protocols for active surveillance (AS) are commonly based on digital rectal examination, prostate-specific antigen (PSA), and standard transrectal biopsy, meaning that initial classification errors and inaccurate lesion monitoring can occur. Protocol-based biopsies are performed to assess changes in cancer grade and extent at prespecified intervals, but this approach represents a barrier to AS adherence and tolerability. There is evidence to support the use of magnetic resonance imaging (MRI) during AS, as this technique (associated with favourable PSA kinetics) offers an opportunity to follow patients on AS without the need for routine, protocol-based biopsies in the absence of signs of radiological progression provided that image quality, interpretation, and reporting of serial imaging are of the highest standards. Patient summary: In this report we looked at the role of magnetic resonance imaging (MRI) scans in avoiding unnecessary prostate biopsies for patients being monitored for low- or intermediate-risk prostate cancer. We conclude that patients on active surveillance can be monitored with MRI scans over time and that biopsies could be used only when there are changes on MRI or a rising prostate-specific antigen (PSA) not explained by an increase in prostate size

    Unsupervised Domain Adaptation with Semantic Consistency across Heterogeneous Modalities for MRI Prostate Lesion Segmentation

    Get PDF
    Any novel medical imaging modality that differs from previous protocols e.g. in the number of imaging channels, introduces a new domain that is heterogeneous from previous ones. This common medical imaging scenario is rarely considered in the domain adaptation literature, which handles shifts across domains of the same dimensionality. In our work we rely on stochastic generative modeling to translate across two heterogeneous domains at pixel space and introduce two new loss functions that promote semantic consistency. Firstly, we introduce a semantic cycle-consistency loss in the source domain to ensure that the translation preserves the semantics. Secondly, we introduce a pseudo-labelling loss, where we translate target data to source, label them by a source-domain network, and use the generated pseudo-labels to supervise the target-domain network. Our results show that this allows us to extract systematically better representations for the target domain. In particular, we address the challenge of enhancing performance on VERDICT-MRI, an advanced diffusion-weighted imaging technique, by exploiting labeled mp-MRI data. When compared to several unsupervised domain adaptation approaches, our approach yields substantial improvements, that consistently carry over to the semi-supervised and supervised learning settings

    Sleep and psychological characteristics in habitual self-awakeners and forced awakeners.

    Get PDF
    Previous studies described the modifications of physiological and behavioural variables associated with self-awakening, while only few studies assessed subjective sleep quality and psychological characteristics in habitual self-awakeners. Here we investigated self-reported sleep habits and features, as well as psychological variables of habitual self-awakeners and forced-awakeners, with special regard to subjective sleep quality, personality characteristics, anxiety and depression symptoms. In our sample, the prevalence of habitual self-awakeners was 15.1%. Compared to forced-awakeners, habitual self-awakeners showed more regular sleep/wake schedules and were more frequently morning types. Moreover, habitual self-awakeners referred to be more satisfied about their sleep, to wake up more easily in the morning, to need less time to get out of bed and to feel more refreshed upon awakening than forced-awakeners. We also observed an association between the habit of self-awakening and the "ability" to set the awakening to an unusual time. Concerning psychological features, habitual self-awakeners showed higher scores in Conscientiousness and Openness and lower scores in Extraversion compared to forced-awakeners, whereas no differences between groups emerged for anxiety and depression levels. In conclusion, our findings point to an association between the habit of self-awakening and good subjective sleep quality. In this perspective, future research should objectively test in detail the effects of the self-awakening habit on sleep structure and organization, taking into account also microstructural sleep features
    • …
    corecore